Hello Community members and moderators,
I already update panel firmware to version: FWA-XD1-PAN-V-0114.00 believing that communication protocol options would update those types supported in CtrlX drive firmware version: FWA-XD1-AXS-V-0316N-NN.00 (mainly new Ethercat CoE protocol only available in newer versions ) but that did not happened. Do you know how to update that new option in the scroll window of this section (comm. protocol)? Only option available are: innactive, Ethercat SoE and Sercos...
Beside that question, is there any place where panel firmware changes and new features could be found documented?
Thank you very much in advance.
Solved! Go to Solution.
06-12-2023 04:19 PM
Unfortunately EtherCAT CoE protocol cannot be selected via the panel. At the very moment it could only be selected via ctrlX DRIVE Engineering, see.
Mind that after change of master communication a reboot is necessary.