Every shape drawn in the visualization comes up with " The entry <Font-Standard> is not defined by your currently active visualization style..." where / how do you define a standard font and why isn't it standard. Note: none of these objects have text so it really doesn't make any difference except I cant see any warnings there are 140 of these and it quits.
Solved! Go to Solution.
06-08-2023 11:12 PM
Are you using webiq or codesys visu?
06-09-2023 08:25 AM
This is not a WebIQ error message.
06-09-2023 02:56 PM
codesys visu
06-09-2023 07:15 PM
06-09-2023 07:52 PM
OK, I get this message for every item that overlaps another. I put labels on the screen and then put a rectangle behind to group them visually and the software wants to warn me it might not appear as it does due to which layer. If anyone here is part of the development, we need a more direct message and a way to toggle it off as we do with other messages
.
06-09-2023 08:29 PM
I must be the only one using this thing. First 25 messages point to the numberpad in the onboard library.
06-21-2023 06:30 AM - edited 06-22-2023 07:00 AM
Moved to corresponding sub forum CODESYS - PLC Add-ons.
06-21-2023 02:39 PM
I don't know where you moved it to, but I've found a solution. The sample program provided by my supplier had no visualization style selected. Once I chose Basic Style it compiled without warnings. Visualization Styles dialog is found in the Tools menu/Options scroll down to Visualization Styles to see the dialog. Use no style, use "none", use "flat style" all do not compile the numpad. Choose "Basic Style" to get rid of the 90 warnings associated with the numberpad.