FORUM CTRLX AUTOMATION
ctrlX World Partner Apps for ctrlX AUTOMATION
Dear Community User! We are updating our platform to a new
system.
Read more: Important
information on the platform change.
10-07-2024 11:16 AM - edited 10-07-2024 12:25 PM
Hello,
Is it possible to reset a Safex from ctrlX Core via Ethercat?
Also, I tried with the Start/Reset block and it works with a button:
But I need without physical button. Is it possible via filedbus from ctrlX Core??
Thanks!!
Solved! Go to Solution.
10-08-2024 08:46 PM
Hello @joelfernandez ,
It is possible to reset from ctrlX CORE but not directly. What I mean by this is you would have to send a bit from ctrlX CORE via Functional exchange (EtherCAT) to SAFEX. Then link this bit to a SAFEX output that is wired to a SAFEX input defined as Start / Reset like you did with the physical button.
The other ways to reset are:
HTH