Functional Description
A crate is to be transported via a conveyor belt. The crate is to be transported from A to B via two conveyor belts. After pressing the start button, the crate is to be placed on the conveyor belt. By occupying the sensor (B1), conveyor belt 1 is started and the crate is transported to the next sensor (B2). After occupying the sensor (B2), conveyor belt 2 is started and the crate is conveyed to the next sensor (B3). After leaving the sensor (B3), the crate lands on the ramp and the system switches off.
In/Output assignment
The in- and outputs of the model are assigned as follows (the designation input or output refers to the connected controller):
Input Nr. | Name | Factory I/O Variable name | Typ | Specification |
1 | S1 | I_Start | BOOL | Start button (NO) |
2 |
B1 |
I_Sensor_1 | BOOL | Sensor B1 (light barrier NC) |
3 | B2 | I_Sensor_2 | BOOL | Sensor B2 (light barrier NC) |
4 | B3 | I_Sensor_3 | BOOL | Sensor B3 (light barrier NC) |
Output Nr. | Name | Factory I/O Variable name | Typ | Specification |
1 | O1 | O_Conveyor_1_ON | BOOL | Conveyor belt entrance on |
2 | O2 | O_Conveyor_2_ON | BOOL | Conveyor belt exit on |
3 | O3 | O_Load_Package | BOOL | Load package |
How-to
Support
Forum ctrlX World Topics
support@selmo.at 1)
Selmo Helpcenter
Related Links
The Company
Selmo Technology GmbH rethinks machine programming and reduces complexity for the programmer. We offer an alternative for manual programming of processes and can translate the process model directly into a PLC program through our algorithm. The Selmo Solution can be learned and applied quickly and easily and immediately creates a standardisation of PLC programming.
FOR SOFTWARE THAT NEVER LETS YOU DOWN
1) Note on data protection
The email is sent directly to the partner company! This company is responsible for the processing of the data contained. Please read their data protection information before sending this email! Bosch Rexroth is not responsible for the use of the partner company's support.
You must be a registered user to add a comment. If you've already registered, sign in. Otherwise, register and sign in.