Hello Tasty_Tech, for selecting a mains filter, the mains input continuous current in A is relevant.
XCD2-W2323:
Mains input continuous current at ULN_nenn and PDC_cont (three-phase, with mains choke) in A (ILN) = 15,9
Mains input continuous current at ULN_nenn and PDC_cont (three-phase, without mains choke) in A (ILN) = 8,1
NFD03.1-480-016:
Rated current mains filter in A = 16
Looking at the current, the mains filter fits to the converter. If a deeper consideration is required please contact our colleagues in product management.