Dear Community, our sales partner is recently testing with our Oscilloscope APP and found out a magnificent delay in signal tracking. In the picture, the test engineer is tracking S-0-0047 Position Command Value and S-0-0051 Position Feedback Value. For visualizatoin, he used both Oscilloscope APP in ctrlX CORE and oscilloscope function in ctrlX Drive engineering to track the signal values. After comparison, the result shows that there is an apparent delay of signal incoming about 5~6 cycle time in the Oscilloscope APP which is running on ctrlX CORE as real-time task. They also tried with ctrlX CORE X3 and X7, and both hardware gave the same result. Automation Core 1.20.1 / Oscilloscope APP 1.20.1 / EtherCAT Master APP 1.20.1 Is this a bug or any configuration mistake? Thanks, Hui
... View more