FORUM CTRLX AUTOMATION
ctrlX World Partner Apps for ctrlX AUTOMATION
07-12-2023 03:29 PM
Hello,
Currently we are using a light curtain with OSSD signals in a Pnoz and we would like to use it in the SAFEX-C.15 but in the Pnoz we use it with the Manual Start function.
In can only find the Automatic Start and Monitored Start in the SAFEX-C.15, is there a possibility to use a Manual start of the light curtain (with an start/reset button) ?
At the moment I programmed it as an auto start with a flip-flop in the program, to realise the same functionality. But a manual start to reset the light curtain would be a nice option.
See the attached pictures
Solved! Go to Solution.
07-14-2023 04:35 PM
Hi @WEMO_MPA,
From what I understand what you need is indeed the "Start Type": Monitored.
Then, on the properties of the Start/Reset Button you have to check the property "Use for Monitored Start Up".
Then you need to link them in the Functional scheme like this:
Let me know if this helps.
Best Regards,
BRamos
07-18-2023 06:47 PM
07-19-2023 07:50 AM
Hello BRamos,
I think this will do the Job as it did at the Pnoz Multi.
Thank you for the explanation.
Kind Regards,
Mike