Hello,
This topic is relevent to ctrlX MOTION also but I think it starts with the I/O. For XM we can use S20-DIDO-2/1-OVS locally or on S3 bus coupler for high-resolution capturing of positions (e.g. for registration) and firing outputs (e.g. glue or camera on a web process). These modules are supported by ML_TouchProbe and MB_DigitalCamSwitchOvsType02 function blocks in the MLC. Are there oversampling modules planned for ctrlX I/O? And/or will it be possible to use S20-DIDO-2/1-OVS with the S20-EC-BK?
Beckhoff has some EtherCAT oversampling modules:
https://www.beckhoff.com/en-us/products/i-o/ethercat-terminals/el2xxx-digital-output/el2262.html
https://www.beckhoff.com/en-us/products/i-o/ethercat-terminals/el2xxx-digital-output/el2258.html
Best regards,
Brian